TR3000 Series current loops

TR3000 series current sensor is used for AC current measurement, the measured current is up to 400A RMS, the maximum pulse current is 100KA, the bandwidth is 50MHZ, the rise time is 200ns, and the diameter of the platinum port is about 50mm; Standard BNC output interface, can be connected to any manufacturer oscilloscope: add the standard accessory BNC to banana socket, which can be connected to a digital multimeter. Widely used in high-end medical multi-band current sensing; Square wave, triangle wave passive mutual inductance, laboratory broadband current research, lightning surge waveform observation, switch short-circuit current detection.

Features:
• Bandwidth: 10Hz~50MHz
• Current measurement range: 10mA to 400ARms
• Maximum pulse peak current 200KA
• Current conversion ratio 1V/1A
• Accuracy class: 1%
• Maximum diameter∅50mm
  • Compatible with BNC interface oscilloscopes

ModelTR3034TR3034ATR3052TR3022TR3015TR3011
Bandwidth10Hz~2MHz10Hz~2MHz10Hz~50MHz10Hz~20MHz10Hz~10MHz10Hz~5MHz
Rise time≤200ns




Enter the typeAC




precision±1%    


Current conversion ratio1mV/A1mV/A1V/A100mV/A50mV/A10mV/A
Minimum RMS100mA50mA5mA10mA20mA50mA
Maximum RMS400A  200A  2A  20A  50A  10A  
Maximum pulse peak current20KA100KA200A2000A4000A10000A
Jaw diameter∅50mm∅14mm
Oscilloscope input impedance1MΩ
Interface typeBNC
Cable length100cm
Working environment0~40°C,80%orless
Storage requirements-10~45°C°C,80%orless
Weight720g520g380g