TR3000 series current sensors are used for AC current measurement. The measured current is as high as 400A effective value, the maximum pulse current is 100KA, the bandwidth is 50MHZ, the rise time is 200ns, and the platinum port diameter is about 50mm. The standard BNC output interface can be connected to any manufacturer's oscilloscope: the standard accessory BNC to banana socket is added to realize the connection with the digital multimeter. Widely used in high-end medical multi-band current sensing; square wave, triangle wave passive mutual inductance, laboratory broadband current research, lightning surge waveform observation, switch short-circuit current detection.
Product Features
• Bandwidth: 10Hz ~ 50MHz
• Current measurement range: 10mA to 400ARms
• Maximum pulse peak current 200KA
• Current conversion ratio 1V/1A
• Accuracy class 1%
• Maximum diameter ∅ 50mm
• Compatible with BNC Interface Oscilloscope
![]() |
Ultra-high pulse current probeThe current loop adopts standard BNC interface, which seamlessly adapts to mainstream oscilloscope brands such as Tektronix, Rhodes, Sis, Puyuan, etc. Plug and play is not required. Support DC-2MHz wide-band current measurement, from milliampere standby power consumption to 100,000 ampere surge current can be accurately captured. The industrial-grade shielding design effectively suppresses electromagnetic interference, and can still output pure waveforms even in strong noise scenarios such as frequency converters and motor drives. |
Numerical measurement functionThrough the complimentary BNC to banana plug, the mV voltage signal output by the current probe is connected to the multimeter to directly read the AC current value. This scheme is suitable for mainstream brand multimeters such as Tektronix and Fluke. It uses its mV gear to analyze the voltage of 0.1mV ~ 1000mV with high precision (1%) and automatically converts it into 1mA-100A current (according to probe sensitivity). |
![]() |
![]() |
Surge Waveform CaptureDesigned for μs surge current observation, the 200ns transient response capability of the current loop accurately captures the wave head time (1.2μs ± 30%) and half peak characteristics of 100kA lightning strike waveform. BNC interface directly connected to the oscilloscope, combined with poor grounding sound and light alarm function to ensure test safety. Hard probe with 50mm diameter, suitable for photovoltaic lightning protection system failure point positioning. |
Start-up current testAt the moment when the motor starts, the rotor is in a static state, and the stator winding generates a rotating magnetic field after the power is turned on. At this time, the magnetic field cuts the rotor winding at the maximum relative speed (synchronous speed), and a very high potential is induced in the rotor conductor, thereby generating a large current. The magnetic flux generated by this current will cancel the stator magnetic field, and the stator is forced to input a larger current to maintain the magnetic flux matching the power supply voltage, forming an initial current peak. |
![]() |
Model | TR3034A |
Bandwidth | 10Hz~2MHz |
Rise time | ≤200ns |
Input Type | AC |
Accuracy | ±1% |
Current conversion ratio | 1mV/A |
Minimum effective value | 50mA |
Maximum effective value | 200A |
Maximum pulse peak current | 100KA |
Jaw diamete | ∅14mm |
Oscilloscope Input Impedance | 1MΩ |
Interface Type | BNC |
Cable length | 100cm |
Working environment | 0~40°C,80%orless |
Storage requirements | -10~45°C°C,80%orless |
Weight | 520g |