Current probes

TR3015

50A / 10MHz Current loop

TR3000 series current sensors are used for AC current measurement. The measured current is as high as 400A effective value, the maximum pulse current is 100KA, the bandwidth is 50MHZ, the rise time is 200ns, and the platinum port diameter is about 50mm. The standard BNC output interface can be connected to any manufacturer's oscilloscope: the standard accessory BNC to banana socket is added to realize the connection with the digital multimeter. Widely used in high-end medical multi-band current sensing; square wave, triangle wave passive mutual inductance, laboratory broadband current research, lightning surge waveform observation, switch short-circuit current detection.

Product Features
• Bandwidth: 10Hz ~ 50MHz
• Current measurement range: 10mA to 400ARms
• Maximum pulse peak current 200KA
• Current conversion ratio 1V/1A
• Accuracy class 1%
• aximum diameter∅50mm
• Compatible with BNC Interface Oscilloscope

Intermediate frequency current loop

The current loop achieves multimeter-level operating efficiency with a common interface. The pure AC measurement capability covers the 10mA-50A range, which is suitable for inverter harmonic analysis, motor starting current detection and other scenarios.

Numerical measurement function

BNC turn banana head has built-in isolation layer to block the high voltage risk of ground loop and ensure the safety of mV measurement of multimeter. The current probe output signal is electrically isolated and then connected to the multimeter. Operation specification: connect the conversion head first and then power on. It is suitable for Fluke 87V contour protection multimeter and zero accident for on-site measurement of high voltage motor control cabinet.

Precision Electronics R & D Applications

10mA ~ 4000A pulse current coverage, winding mode to enhance the small current sensitivity. It is suitable for laboratory broadband current research, lightning surge waveform observation, switch short-circuit current monitoring, and high-end medical multi-band current sensing measurement.

Start-up current test

The instantaneous current when the motor starts (also known as the starting current or locked-rotor current) is a key physical phenomenon in the motor starting process, and its value is usually 4 to 7 times the rated current. The waveform can be measured by selecting the appropriate current probe.

ModelTR3015
Bandwidth10Hz~10MHz
Rise time≤50ns
Input TypeAC
Accuracy±1%  
Current conversion ratio50mV/A
Minimum effective value20mA
Maximum effective value50A  
Maximum pulse peak current4000A
Jaw diameter∅14mm
Oscilloscope Input Impedance1MΩ
Interface TypeBNC
Cable length100cm
Working environment0~40°C,80%orless
Storage requirements-10~45°C°C,80%orless
Weight380g

There are currently no application cases available

There are currently no films available

Customer
Customer service

contact information

Suzhou

address:Building 9, No. 269, Xinfeng Road, Xukou Town, Wuzhong District, Suzhou, China

Telephone:0512-66559708

Technical support

If you have any other questions, you can contact us by email

Contact Email

marketing@tronovo.com