TR3000 series current sensors are used for AC current measurement. The measured current is as high as 400A effective value, the maximum pulse current is 100KA, the bandwidth is 50MHZ, the rise time is 200ns, and the platinum port diameter is about 50mm. The standard BNC output interface can be connected to any manufacturer's oscilloscope: the standard accessory BNC to banana socket is added to realize the connection with the digital multimeter. Widely used in high-end medical multi-band current sensing; square wave, triangle wave passive mutual inductance, laboratory broadband current research, lightning surge waveform observation, switch short-circuit current detection.
Product Features
• Bandwidth: 10Hz ~ 50MHz
• Current measurement range: 10mA to 400ARms
• Maximum pulse peak current 200KA
• Current conversion ratio 1V/1A
• Accuracy class 1%
• aximum diameter∅50mm
• Compatible with BNC Interface Oscilloscope
![]() |
Intermediate frequency current loopThe current loop achieves multimeter-level operating efficiency with a common interface. The pure AC measurement capability covers the 10mA-50A range, which is suitable for inverter harmonic analysis, motor starting current detection and other scenarios. |
Numerical measurement functionBNC turn banana head has built-in isolation layer to block the high voltage risk of ground loop and ensure the safety of mV measurement of multimeter. The current probe output signal is electrically isolated and then connected to the multimeter. Operation specification: connect the conversion head first and then power on. It is suitable for Fluke 87V contour protection multimeter and zero accident for on-site measurement of high voltage motor control cabinet. |
![]() |
![]() |
Precision Electronics R & D Applications10mA ~ 4000A pulse current coverage, winding mode to enhance the small current sensitivity. It is suitable for laboratory broadband current research, lightning surge waveform observation, switch short-circuit current monitoring, and high-end medical multi-band current sensing measurement. |
Start-up current testThe instantaneous current when the motor starts (also known as the starting current or locked-rotor current) is a key physical phenomenon in the motor starting process, and its value is usually 4 to 7 times the rated current. The waveform can be measured by selecting the appropriate current probe. |
![]() |
Model | TR3015 |
Bandwidth | 10Hz~10MHz |
Rise time | ≤50ns |
Input Type | AC |
Accuracy | ±1% |
Current conversion ratio | 50mV/A |
Minimum effective value | 20mA |
Maximum effective value | 50A |
Maximum pulse peak current | 4000A |
Jaw diameter | ∅14mm |
Oscilloscope Input Impedance | 1MΩ |
Interface Type | BNC |
Cable length | 100cm |
Working environment | 0~40°C,80%orless |
Storage requirements | -10~45°C°C,80%orless |
Weight | 380g |