The high-voltage passive probe is designed for accurate measurement of high-frequency and high-voltage signals, supporting ground-referenced transient voltage measurement up to 50KV, and a bandwidth of 100MHz can accurately capture high-voltage pulse signals. Its innovative multi-layer shielding structure with insulated protective enclosure meets IEC61010 safety standards to ensure the safety of operators and equipment. The probe has a built-in MΩ high-impedance input to minimize the load effect on the circuit under test and ensures signal integrity through dynamic compensation technology. It adapts to mainstream oscilloscopes through standard BNC interfaces, supports high-risk scenarios such as switching power supply testing, IGBT drive analysis, and power system surge monitoring, and provides safe and reliable high-voltage measurement solutions for power electronics research and development and new energy equipment maintenance.
Features:
• Maximum voltage:30KV DC+ACpeak
• Bandwidth up to100MHz
• Input impedance 300MΩ
• Fixed attenuation ratio of 1000:1
• It can be connected to a multimeter with an impedance matcher
• Ultra-low noise
![]() |
High-frequency passive high-voltage probesThe standard BNC interface is a universal physical connection solution in the field of oscilloscopes and is compatible with all major oscilloscope brands. Whether it is an imported flagship (such as Tektronix TBS2000B, Keysight) or a domestic model (Puyuan RIGOL, Dingyang SDS5000X), it can achieve "plug and play", eliminating cumbersome settings such as probe identification and impedance matching. |
High insulationThe high-voltage probe is made of cutting-edge insulation materials combined with advanced manufacturing processes, and its core advantage lies in its excellent insulation performance. The design effectively isolates high-voltage interference and potential leakage risks, ensuring that the measurement signal remains pure, stable, accurate and reliable even in ultra-high voltage environments. The excellent insulation performance eliminates false detection and potential safety hazards, and directly improves the safety of equipment and operator protection. |
![]() |
![]() |
Low input capacitanceWhen the probe needs to be calibrated, the probe Hole 1 interface can be adjusted, which is a 200Hz square wave adjustment point, and the signal generator can be used to calibrate. This product has been adjusted to Hole 2 and Hole 3 when leaving the factory, please do not adjust Hole 2 and Hole 3 adjustment points for non-professionals. |
Ground loopsWhen measuring high-frequency voltages above 40MHz, please use this alligator clip to directly ground to get a better frequency response. |
![]() |
![]() |
Low noiseThe advanced low-noise circuit design effectively suppresses the coupling of environmental electromagnetic interference and internal noise. Reducing crosstalk by optimizing component layout, combined with a new grounding architecture to eliminate ground loop noise, ensures pure and stable signal transmission. |
Model | TR9330D |
Bandwidth | DC~100MHz |
Rise time | 3.5nS |
Attenuation scale | 1000:1 |
Input impedance | 300MΩ |
Maximum input:DC+AC peak | 30KV CATII ≤30s |
Maximum input:AC RMS | 21KV CATII ≤30s |
Maximum load current | 90uA |
Noise-to-signal ratio | >60dB at 1KHz;>50dB at 1MHz |
DC signal error value | ≦3% (0~35kV) Full Scale Input Range |
Temperature coefficient | ≦200 PPM/℃ |
Match capacitance adjustment range | 10PF~35PF |
Safety inspection | Compliant with EN61010-031 CATI specification |
Test line length | 1.8m士0.2m |
Operating temperature and humidity | 0~40°C,80% or less |
Store temperature and humidity | -10~45°C,80% or less |
Size | 90mmx90mmX38lmm |
Weight | 606g |
Operating temperature and humidity | 0~40℃,80% or less |