The high-voltage passive probe is designed for accurate measurement of high-frequency and high-voltage signals, supporting ground-referenced transient voltage measurement up to 20KV, and 100MHz bandwidth can accurately capture high-voltage pulse signals. Its innovative multi-layer shielding structure with insulated protective enclosure meets IEC61010 safety standards to ensure the safety of operators and equipment. The probe has a built-in MΩ high-impedance input to minimize the load effect on the circuit under test and ensures signal integrity through dynamic compensation technology. It adapts to mainstream oscilloscopes through standard BNC interfaces, supports high-risk scenarios such as switching power supply testing, IGBT drive analysis, and power system surge monitoring, and provides safe and reliable high-voltage measurement solutions for power electronics research and development and new energy equipment maintenance.
Features:
• Maximum amount of voltage measurement:20KV DC+ACpeak
• Bandwidth up to100MHz
• Input impedance 300MΩ
• Fixed attenuation ratio of 1000:1
• It can be connected to a multimeter with an impedance matcher
• Ultra-low noise
![]() |
Strong compatibility and adaptation to mainstream instrumentsDomestic and imported mainstream brand oscilloscopes, plug and play, no additional configuration is required. can be seamlessly integrated to improve testing efficiency. |
Low noise designIt adopts advanced low-noise circuit design to effectively suppress environmental interference. |
![]() |
![]() |
Safe and reliableThe high-voltage probe adopts high-quality insulating materials and advanced manufacturing technology, which has very good insulation performance. |
A variety of accessories are suitable for different scenariosFor different application needs, choosing the right accessories can increase work efficiency. |
![]() |
![]() |
Packed in a storage boxSafe transportation, convenient and neat storage. |
Model | TR9320D |
Bandwidth | DC~100MHz |
Rise time | 3.5nS |
Attenuation scale | 1000:1 |
Input impedance | 300MΩ |
Maximum input:DC+AC peak | 20KV CATII ≤30s |
Maximum input:AC RMS | 14KV CATII ≤30s |
Maximum load current | 90uA |
Noise-to-signal ratio | >60dB at 1KHz;>50dB at 1MHz |
DC signal error value | ≦3% (0~35kV) Full Scale Input Range |
Temperature coefficient | ≦200 PPM/℃ |
Match capacitance adjustment range | 10PF~35PF |
Safety inspection | Compliant with EN61010-031 CATI specification |
Test line length | 1.8m士0.2m |
Operating temperature and humidity | 0~40°C,80% or less |
Store temperature and humidity | -10~45°C,80% or less |
Size | 90mmx90mmX38lmm |
Weight | 606g |
Operating temperature and humidity | 0~40℃,80% or less |
There are currently no application cases available