TR2515 DC resistance tester uses 32-bit Cortex-M3 CPU and 4.3-inch color LCD screen; The highest resistance measurement accuracy of 0.01% and the minimum resistance resolution of 0.1μΩ are second to none in China. Equipped with temperature measurement function, its temperature compensation and temperature conversion function eliminate the influence of ambient temperature on the test work; The offset voltage compensation function can effectively eliminate the electromotive force and contact potential difference of the DUT, and well eliminate the potential error caused by the influence of thermoelectric potential on the contact of the DUT. In particular, the resistance value changes greatly with temperature has a better test effect, and has a statistical analysis function, which can statistically analyze a large number of test data.
Features:
• 4.3-inch 24-bit true color LCD screen with 480×272 resolution
• Optional operation interface in Chinese and English
• The maximum sampling rate is about 100 times/second
• 5½-digit high-resolution measurement result display
• Highest resistance accuracy: 0.01%, minimum resolution: 0.1uΩ
• Basic temperature accuracy: 0.1°C
• Support PT100 and PT500 temperature sensors
• Low voltage test mode, effectively protect the DUT
• Temperature conversion function (Δt)
• Temperature Compensation (TC)
• Offset Voltage Compensation (OVC)
![]() |
True Color LCDThe DC low resistance tester is equipped with a 4.3-inch 24-bit true color LCD screen with 480x 272 high definition resolution showing fine image quality. The test data, curve trend and status mark are displayed in rich colors in layers. The values are clear and easy to read, and the status is clear at a glance. |
Statistical functionThe DC low resistance tester has a built-in comprehensive statistical function, which can automatically calculate the average, maximum and minimum values of batch test data and visually present the data distribution range. The total standard deviation and sampling standard deviation are used to quantify the dispersion degree, and the engineering capability index (dispersion Cp, bias CpK) is matched to scientifically evaluate the stability and quality consistency of the production process. |
![]() |
![]() |
Temperature compensationThe DC low resistance tester has a built-in temperature compensation function, which is compatible with PT100 and PT500 temperature sensors. It can collect the ambient temperature of the measured object in real time and automatically correct the resistance deviation caused by temperature change through an accurate algorithm-the metal resistance changes linearly with temperature. This function compensates the measured value to the equivalent resistance at the standard temperature to avoid the interference of temperature fluctuation on the milliohm measurement. |
User self-calibrationThe DC low resistance tester is equipped with a user self-calibration function, which is extremely easy to operate: only by short-circuiting the test clamp to the clamp, the instrument will clear the inherent interference values such as wire resistance and contact impedance in the current circuit and automatically incorporate them into the compensation reference. |
![]() |
![]() |
Offset voltage compensationThe DC low resistance tester is equipped with an offset voltage compensation function, which can accurately offset the thermal electromotive force interference generated by the measured part due to material contact temperature difference, current on-off transients, etc.-if such microvolt-level micro electromotive force is not compensated, it will be superimposed on the measured voltage, resulting in deviation in low resistance measurement. |
Model | TR2515 |
Display | 24-bit color, RGB true color TFT LCD display with a resolution of 480×272. |
Number of digits | 5½ 位 |
Resistance measurement range | 0.1μΩ—110MΩ |
Resistance range | 20mΩ、200mΩ、2Ω、20Ω、200Ω、2KΩ、20KΩ、100KΩ、1MΩ、10MΩ、100MΩ |
Current | 1A、100mA、100mA、10mA、1mA、100uA、10uA、1uA、100nA |
Measurement accuracy | 0.01% (see instruction manual for details) |
Resistance measurement time | FAST:7ms; MED:22ms; SLOW1:102ms; SLOW2:402ms |
Temperature measurement time | 50±10ms |
Measurement section configuration | Four ends |
Low voltage measurements | Open Circuit Voltage:≤60mV Effective Range:2Ω,20Ω,200Ω,2KΩ |
Thermoelectric potential elimination | √ |
Statistical functions | Mean, Maximum, Minimum, Total Standard Deviation, Sampling Standard Deviation, Engineering Ability Index (Dispersion Cp, Bias Cpk) |
Measurement settings Parameters are saved | 30 Groups |
Temperature measurement | Sensor:PT100,PT500 -10.0℃—299.9℃; Display:-99.9℃—999.9℃ |
Other features | Temperature compensation function, temperature conversion function |
Compare | Signal output: HI/IN/LO Signal: Tweet Mode: OFF, IN, HI/LO Limit Setting Mode: 10 gears, absolute value upper/lower limit, percentage upper and lower limit + nominal value |
Interface configuration | USB DEVICE、USB HOST、RS232、LAN、HANDLER、GPIB(选件) |
There are currently no application cases available